Guidance from Electrical Safety First intended for electrically competent persons. Includes the application of the requirements of the 17th Edition of the IET Wiring Regulations, as amended (BS 7671: 2008 incorporating Amendment 2). Jun 13, 2012  Discuss IEE 17th edition (Amended) in.pdf format and/or iphone/ipad app? In the Electrical Wiring, Theories and Regulations area at ElectriciansForums.net.

With the introduction of the 17th Edition of the IEE Wiring Regulations rapidly approaching, the Electrical Contractors' Association (ECA) has announced it will provide each of its member firms with a free pack containing the17th Edition of the IEE Wiring. THE SCOPE of the 17th Edition is wider. The following list provides an overview of the main changes within the 18th Edition IET Wiring Regulations (publishing 2nd July 2018). This list is not exhaustive as there are many smaller changes throughout the book not included here. Guide to the Wiring Regulations is an outstanding resource for all users of the 17th Edition IEE Wiring Regulations (BS 7671: 2008) including electricians who want a better understanding of the theory behind the Standard, electrical technicians, installation engineers, design engineers, and apprentices. Both trainees and practitioners will find this guide indispensable for understanding the impact of the changes introduced in the 17th Edition (BS 7671: 2008).

Relevant topics on
Electrical installations
Wiring practice by region or country
Regulation of electrical installations
Cabling and accessories
Switching and protection devices

British StandardBS 7671 'Requirements for Electrical Installations. IET Wiring Regulations', informally called in the electrical community The 'Regs', is the national standard in the United Kingdom for electrical installation and the safety of electrical wiring in domestic, commercial, industrial, and other buildings, also in special installations and locations, such as marinas or caravan parks.[1]

In general, BS 7671 applies to circuits supplied at nominal voltages up to and including 1000 volts AC or 1500 volts DC. The standard therefore covers the 230 volt 50 Hz AC mains supply used in the UK for houses, offices, and commerce. It did not become a recognized British Standard until the publication of the 16th edition in 1992. The standard takes account of the technical substance of agreements reached in CENELEC[2]

Based on the IEC 60364 series, the 18th Edition of. BS 7671 Wiring regulations covers the electrical installation of buildings including the use of surge protection. The 18th Edition of BS 7671 applies to the design, erection and verification of electrical installations, and also to additions and alterations to existing installations. The new 17th Edition of the wiring regulations are expected to be implemented from 31st June 2008. There are a significant number of changes and upgrades to the current 16th Edition regulations, including alignment to international standards.

The current version is BS 7671:2018 (the 18th Edition) issued in 2018 and comes into effect from 1 January 2019. [3][3] BS 7671 is also used as a national standard by Mauritius, St Lucia, Saint Vincent and the Grenadines, Sierra Leone, Sri Lanka, Trinidad and Tobago, Uganda, Cyprus, and several other countries, which base their wiring regulations on BS 7671.

  • 2History of BS 7671 and predecessor standards

Compilation and publication[edit]

The standard is maintained by the Joint IET/BSI Technical Committee JPEL/64, the UK National Committee for Wiring Regulations, and published by the IET (formerly IEE). Although the IET and BSI are non-governmental organisations and the Wiring Regulations are non-statutory, they are referenced in several UK statutory instruments, and in most cases, for practical purposes, have legal force as the appropriate method of electric wiring.[4]

The BSI (British Standards Institute) publishes numerous titles concerning acceptable standards of design/safety/quality across different fields.

History of BS 7671 and predecessor standards[edit]

The first edition was published in 1882 as the 'Rules and Regulations for the Prevention of Fire Risks arising from Electric Lighting.' The title became 'General Rules recommended for Wiring for the Supply of Electrical Energy' with the third edition in 1897, 'Wiring Rules' with the fifth edition of 1907, and settled at 'Regulations for the Electrical Equipment of Buildings' with the eighth edition in 1924.

Since the 15th edition (1981), these regulations have closely followed the corresponding international standard IEC 60364. In 1992, the IEE Wiring Regulations became British Standard BS 7671 so that the legal enforcement of their requirements was easier both with regard to the Electricity at Work regulations and from an international point of view.[5] They are now treated similar to other British Standards. BS 7671 has converged towards (and is largely based on) the European Committee for Electrotechnical Standardization (CENELEC) harmonisation documents, and therefore is technically very similar to the current wiring regulations of other European countries.

1st Edition[edit]

'Rules and Regulations for the Prevention of Fire Risks arising from Electric Lighting.' - Two core cable, line and neutral, no earth. The protection was a re-wirable fuse.

17th Edition[edit]

The 17th edition, released in January 2008 and amended in 2011 ('Amendment 1'), 2013 ('Amendment 2') and January 2015 ('Amendment 3') became effective for all installations designed after 1 July 2008.[6] One of the more significant changes is (chapter 41) that 30 mA RCDs will be required for socket outlets that are for use by ordinary persons and are intended for general use. This improves the level of protection against electrical shock in the UK to a level comparable to that in other EU countries. The 17th edition and its amendments incorporated new sections relating to microgeneration and solar photovoltaic systems, non-combustible consumer units, RCDs, and breakers (including high resilience breaker layout).

  • As originally published highlights - RCDs required for most outlets
  • Amendment 1 highlights - high resilience consumer units
  • Amendment 2 highlights - electric vehicle charging added, earlier change incorporated for medical locations[7]
  • Amendment 3 highlights - non combustible consumer units/enclosures[3]

Iee Wiring Regulations 17th Edition Pdf Download

Timeline[edit]

DateEdition / changeInformation
18821st EditionTitled ‘Rules and Regulations for the prevention of Fire Risks Arising from Electric Lighting’, and known as the 'Wiring Rules'
18882nd EditionTitled 'Wiring Rules & Regulations in Buildings
18973rd EditionTitled ‘General Rules recommended for Wiring for the Supply of Electrical Energy’
19034th Editionissued as IEE Wiring Regulations, called ‘Wiring Rules’
19075th EditionIssued as IEE Wiring Regulations
19116th EditionIssued as IEE Wiring Regulations
19167th EditionIssued as IEE Wiring Regulations
19248th EditionIssued as IEE Wiring Regulations ‘Regulations for the Electrical Equipment of Buildings’
19279th EditionIssued as IEE Wiring Regulations
193410th EditionIssued as IEE Wiring Regulations
193911th EditionIssued as IEE Wiring Regulations. Revised in 1943, reprint with minor amendments in 1945, supplement in 1946, further revised in 1948
195012th EditionIssued as IEE Wiring Regulations. Supplement issued 1954
195513th EditionIssued as IEE Wiring Regulations. Reprinted in 1958, 1961, 1962, 1964
196614th EditionIssued as IEE Wiring Regulations. Reprinted in 1968, 1969, 1969 again (metric units[verification needed]), 1970 (in metric units), 1972, 1973, 1974, 1976
198115th EditionIssued as IEE Wiring Regulations. (Possibly reprinted 1983, 1984, 1986, 1987, 1988?[verification needed])
199116th EditionIssued as IEE Wiring Regulations. Reprinted with amendments 1992, 1994, 1997, 2000, 2001, 2004
1992BSI adopts as a standardWiring Regulations adopted by the British Standards Institute as BS 7671
1992LegislationElectricity at Work Regulations come fully into effect in Northern Ireland
2004Incorporated into building regulationsPart P of the Building Regulations ('Requirements for Electrical Installations') comes into force, covering legal requirements for UK electrical installations. The guidance in the Approved Documents refers to BS 7671 as being one way to achieve compliance. The version in force when the law came into effect was the 16th edition, BS 7671:2001, as amended in 2002 and 2004.
200817th EditionAmended 2015 ('Amendment no. 3') - current standard as of October 2016
201818th EditionExpected to introduce energy efficiency performance levels and the use of arc fault detection devices.[8]

Made available on 2 July 2018.

See also[edit]

References[edit]

Edition
  1. ^BS7671 chapter 11 - scope
  2. ^BS7671: Preface
  3. ^ abc'IET launches Amendment to Wiring Regulations'. www.theiet.org. The IET. Retrieved 1 March 2018.
  4. ^'Regulatory Requirements'(PDF). p. 3.
  5. ^Electrician's guide to the 17th edition of the IEE wiring regulations. 3rd edition pub 2012 John Whitfield
  6. ^Geoff Cronshaw: The 17th edition: a brief overview. IEE Wiring Matters, Summer 2007.
  7. ^'IET launches Amendment 3 to BS 7671:2008'. Voltimum UK. Retrieved 1 March 2018.
  8. ^Whitton, Nicole (2016). 'BS 7671: the 18th Edition report'. electrical.theiet.org. IET Electrical. Retrieved 8 February 2018.
Wiring

17th Edition Iee Regulations

External links[edit]

Retrieved from 'https://en.wikipedia.org/w/index.php?title=BS_7671&oldid=909008433'